[1]巢世友,刘永阔,吴国华,等.基于JTopmeret的非能动安全型核电站凝结水系统仿真研究[J].应用科技,2016,(01):76-80.[doi:10.11991/yykj.201505020]
 CHAO Shiyou,LIU Yongkuo,WU Guohua,et al.Dynamic simulation of the condensate system inpassive safe nuclear power plants based on JTopmeret[J].yykj,2016,(01):76-80.[doi:10.11991/yykj.201505020]
点击复制

基于JTopmeret的非能动安全型核电站凝结水系统仿真研究(/HTML)
分享到:

《应用科技》[ISSN:1009-671X/CN:23-1191/U]

卷:
期数:
2016年01期
页码:
76-80
栏目:
动力与能源工程
出版日期:
2016-02-05

文章信息/Info

Title:
Dynamic simulation of the condensate system inpassive safe nuclear power plants based on JTopmeret
作者:
巢世友12 刘永阔1 吴国华1 段智勇1
1. 哈尔滨工程大学 核安全与仿真技术国防重点学科实验室, 黑龙江 哈尔滨 150001;
2. 东方电气(广州)重型机器有限公司, 广东 广州 511455
Author(s):
CHAO Shiyou12 LIU Yongkuo1 WU Guohua1 DUAN Zhiyong1
1. Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin 150001, China;
2. Dongfang(Guang Zhou) Heavy Machinery Co., Ltd., Guangzhou 511455, China
关键词:
核电站凝结水系统核能安全动态仿真
Keywords:
nuclear power plants(NPPs)condensate system(CDS)nuclear saftydynamic simulation
分类号:
TL7
DOI:
10.11991/yykj.201505020
文献标志码:
A
摘要:
采用JTopmeret两相流建模工具和SimExec实时仿真软件平台建立非能动安全型核电站凝结水系统仿真模型,实现了核电站凝结水系统的动态仿真。在此基础上进行典型稳态工况以及动态工况的仿真计算和分析。结果表明,该模型的稳态仿真计算结果与设计值吻合,动态过程中参数变化与实际系统特性吻合,验证了仿真模型的合理性和正确性。
Abstract:
A simulation model for the condensate system(CDS) in passive safe nuclear power plants(NPPs) was established using the two-phase modeling tool JTopmeret and the real-time simulation platform SimExec,realizing the dynamic simulation of CDS in NPPs.Based on the established simulation model,the steady operating and dynamic operating were calculated.The results show that the dynamic results accord with the characteristics of the actual system,verifying the simulation models is reasonable and correct.

参考文献/References:

[1] 林诚格.非能动安全先进压水堆核电技术[M].北京:原子能出版社,2010:68-72.
[2] 张江红,胡念苏.基于Simulink的电站凝结水系统仿真建模[J].电力科学与工程,2012(2):75-78.
[3] 胡勇,刘洁臻,曾德良,等.1000MW火电机组凝结水节流系统动态模型研究[J].太原理工大学学报,2014,45(6):818-822.
[4] 林诚格.非能动安全先进核电厂AP1000[M].北京:原子能出版社,2008:126-136.
[5] GSE Systems,Inc.Jtopmeret user guide[M].Sykesville:GSE Systems,Inc.,2006:46-48.
[6] GSE Systems,Inc.Jtopmeret model maintenance guide[M].Sykesville:GSE Systems,Inc.,2000:98-100.
[7] SCHULZ T L.Westinghouse AP1000 advanced passive plant[J].Nuclear engineering and design,2006,236(14/15/16):1547-1557.
[8] PARK H S,CHOI N H,CHANG S K,et al.Experimental study on a two-phase critical flow with a non-condensable gas at high pressure conditions[J].International journal of multiphase Flow,2007,33(11):1222-1236.
[9] PALADINO D,AUBAN O,HUGGENBERGER M,et al.A PANDA integral test on the effect of light gas on a Passive Containment Cooling System(PCCS)[J].Nuclear engineering and design,2011,241(11):4551-4561.
[10] PALADINO D,DREIER J.Passive containment cooling system(PCCS) response with Drywell Gas Recirculation System(DGRS) activated during a postulated Loss of Coolant Accident(LOCA)[J].Nuclear engineering and design,2011,241(9):3925-3934.
[11] PALADINO D,ZBORAY R,BENZ P,et al.Three-gas mixture plume inducing mixing and stratification in a multi-compartment containment[J].Nuclear engineering and design,2010,240(2):210-220.

相似文献/References:

[1]李明岩,彭敏俊,张志俭.核电站非能动余热排出系统误开事故仿真研究[J].应用科技,2009,(12):52.[doi:10.3969/j.issn.1009-671X.2009.12.014]
 LI Ming-yan,PENG Min-jun,ZHANG Zhi-jian.Simulation research of the passive residual heat removal system’s inadvertent opening accident of a nuclear power plant[J].yykj,2009,(01):52.[doi:10.3969/j.issn.1009-671X.2009.12.014]
[2]刘洪涛,彭敏俊,田兆斐,等.核电站给水加热器建模与仿真[J].应用科技,2011,(06):67.[doi:10.3969/j.issn.1009-671X.2011.06.015]
 LIU Hongtao,PENG Minjun,TIAN Zhaofei,et al.Modeling and simulation of the feed-water heater in a nuclear power plant[J].yykj,2011,(01):67.[doi:10.3969/j.issn.1009-671X.2011.06.015]
[3]周国正,张学粮,颜安和.虚拟现实技术在核电站在役检查管理系统中的应用[J].应用科技,2013,(03):54.[doi:10.3969/j.issn.1009-671X.201211002]
 ZHOU Guozheng,ZHANG Xueliang,YAN Anhe.Application of virtual reality to in-service inspection management system for a nuclear power station[J].yykj,2013,(01):54.[doi:10.3969/j.issn.1009-671X.201211002]
[4]段智勇,刘永阔,夏虹,等.核电站故障诊断与故障程度评估方法[J].应用科技,2016,(04):1.[doi:10.11991/yykj.201508032]
 DUAN Zhiyong,LIU Yongkuo,XIA Hong,et al.Fault diagnosis and fault degree evaluation in nuclear power plant[J].yykj,2016,(01):1.[doi:10.11991/yykj.201508032]

备注/Memo

备注/Memo:
收稿日期:2015-05-18;改回日期:。
作者简介:巢世友(1991-),男,助理工程师;刘永阔(1977-),男,副教授,博士.
通讯作者:刘永阔,E-mail:lyk08@126.com.
更新日期/Last Update: 2016-02-17