A method of voltage harmonic error detection based on circuit network structure transformation
作者:
邹练辉1 韩金尅1 黄乐1 梁江东2
1. 广东电网有限责任公司 梅州供电局, 广东 梅州 514000;
2. 武汉武高电气技术有限责任公司, 湖北 武汉 430074
Author(s):
ZOU Lianhui1 HAN Jinke1 HUANG Le1 LIANG Jiangdong2
1. Meizhou Power Supply Bureau, Guangdong Power Grid Co., Ltd., Meizhou 514000, China;
2. Wuhan Wugao Electricity Co., Ltd., Wuhan 430074, China
关键词:
智能电网电能质量检测三角形接线相电压参数谐振星网变换MATLAB仿真谐波畸变
Keywords:
smart electric gridpower quality measurementtriangular connectionphase voltageparametric resonancenetwork transformationMATLAB simulationharmonic distortion
分类号:
TM131.4
DOI:
10.11991/yykj.201611013
文献标志码:
A
摘要:
针对电能特征异常扰动的情况下,探究可靠的电压特征误差测量方法。电能波动、冲击与非线性等质量异常扰动,严重影响供电可靠性,造成了电力用户的经济损失。从理论上分析电压谐波及谐波潮流出现测量误差的机理,构建变压器结构的单相测量等值电路,从而为消除参数谐振影响提供基础。提出了三同阻并行接入积分相电压的测量方案,在不改变原系统运行方式的情况下,通过电路网络结构变换排除参数谐振引入的干扰,通过改造仪器的电压输入回路,实现三相系统从线电压到相电压的转换,最终实现系统电压的准确测量。通过MATLAB仿真计算与现场实际测量结果,表明经过电路变换测量的电压各次谐波畸变率测试结果与输入信号的理论畸变率一致,证明了该方法的可行性。
Abstract:
This paper focuses on the a reliable method for measuring voltage characteristic error under the abnormal disturbance of electric energy characteristic. Abnormal mass disturbance resulted from electric power disturbance, impact, and nonlinearity seriously influence reliability of power supply, and cause economic loss of users. This paper theoretical analyzed voltage harmonics and harmonic power flow measurement error mechanism. In order to eliminate the impact of resonance parameters, the structure of transformer single-phase measurement equivalent circuit was built. The measurement scheme of three phase-to-neutral parallel-input integrated phase voltage was proposed. Without changing the operating mode of the original system, the interference of parametric resonance was eliminated by the circuit network structure transformation and realize transformation from line voltage to phase voltage of the three-phase system by changing instrument’s voltage input circuit, achieving accurate voltage measurement method. The MATLAB simulation and field measurement show that the voltage harmonic distortion measurement result derived from electric circuit transformation measurement is in agreement with theoretical harmonic distortion of input signal, proving feasibility of the method.

参考文献/References:

[1] ?GB/T 14549-1993. 电能质量—公用电网谐波[S]. 北京: 中国标准出版社, 1994: 1-2.
[2] 李薇, 张文, 郑妍.基于改进的小波阈值的电能质量信号去噪[J]. 应用科技, 2012, 39(2): 15-18.
[3] 谢志文. 变电站三次电压谐波测试及抑制[D]. 广州: 华南理工大学, 2012: 54-55.
[4] 王春萌.一种解决中性点不接地系统铁磁谐振问题的新技术[J]. 电气技术, 2014(9): 94-96.
[5] 周默, 孙岩洲. 电网中性点不同接地方式下铁磁谐振的消谐研究[J]. 高压电器, 2015, 51(1): 81-85.
[6] WU L. A Tighter piecewise linear approximation of quadratic cost curves for unit commitment problems[J]. IEEE transactions on power systems, 2011, 26(4): 2581-2583.
[7] RESTREPO J F, GALIANA F D. Assessing the yearly impact of wind power through a new hybrid deterministic/stochastic unit commitment[J]. IEEE transactions on power systems, 2011, 26(1): 401-410.
[8] 戎骏, 胡海涛, 邵洋, 等. 基于敏感度分析的海上风电场谐波谐振研究[J]. 电网技术, 2016, 40(8): 2510-2517.
[9] 周文, 潘朝霞, 刘英等. 220 kV变电站 10 kV母线零序电压测量值异常情况分析[J]. 电力系统及其自动化, 2014(2): 66-68, 83.
[10] 张晶晶, 宋传盼. 电压不平衡分析及解决方案[J]. 贵州电力技术, 2014, 17(12): 30-31, 88.
[11] 陈立伟, 刘欢, 冯驰, 等. Kaiser窗三谱线插值电力谐波分析[J]. 应用科技, 2014, 41(2): 5-11.
[12] 乔立慧, 孔红, 李佳琦. 基于傅立叶方法的铁磁谐振谐波分析[J]. 测控自动化, 2010, 26(25): 230-233.

相似文献/References:

[1]朱涛,顾全,赵川,等.含分布式电源的弱环配电网状态估计[J].应用科技,2015,(04):25.[doi:10.3969/j.issn.1009-671X.201411009]
 ZHU Tao,GU Quan,ZHAO Chuan,et al.State estimation for the weakly meshed distribution network with the distributed power[J].yykj,2015,(06):25.[doi:10.3969/j.issn.1009-671X.201411009]

备注/Memo

备注/Memo:
收稿日期:2016-11-30。
基金项目:广东电网有限责任公司科研项目(K-GD2014-208)
作者简介:邹练辉(1974-),男,工程师
通讯作者:韩金尅,E-mail:hjinke2016@21cn.com
更新日期/Last Update: 2018-01-06